| Main | Product name | Caro Plus Series Home Wallbox |
| Product positioning | PV-ready smart AC wallbox for solar homes, installers, distributors and residential energy projects |
| Product status | New-generation Caro Plus model family; final SKU availability should be confirmed by market and release schedule |
| Market configuration | EU / UK / France product configurations listed in product introduction; final market promotion should follow current certification status |
| Dimensions | 365 × 201 × 99.5 mm (H × W × D) |
| Design level | Automotive-grade design direction for mid-to-high-end residential charging projects |
| Product Model SKU | Type 2 cable version | AC7000-AE-45C3-ENP / AC7000-AB-45C3-ENP | AC011K-AE-55C3-ENP |
| Type 2 socket version | AC7000-BE-45C3-ENP / AC7000-BB-45C3-ENP | Project confirmation required |
| France T2S socket version | AC7000-TE-45C3-ENP | Project confirmation required |
| Output options | Type 2 cable 5m / Type 2 socket / T2S socket for France | Type 2 cable configuration by listed SKU |
| Release note | Product release dates should be confirmed before live market promotion |
| Electrical | Rated power | 7kW | 11kW |
| Power supply | 1P + N + PE | 3P + N + PE |
| Input / output voltage | 230V AC ±20% | 400V AC ±20% |
| Maximum current | 32A | 16A |
| Frequency | 50Hz |
| Charging mode | Mode 3 according to IEC 61851-1 |
| PV & Smart Energy | Solar compatibility | Solar compatible / PV-ready charging direction |
| Charging modes | ECO / MIX / BOOST Mode |
| PV charging value | Zero-emission PV charging and improved solar self-consumption by project configuration |
| PV system integration | Designed for seamless integration with PV systems by supported energy architecture |
| Adjustable current | Adjustable current for optimized PV usage |
| Charging scheduling | App charging scheduling supported |
| Dynamic power pricing path | Can work with load balancing / ECO system for cost-saving charging strategies by project configuration |
| Load Balancing | Dynamic load balancing | Supported by charger / local load balancing controller |
| Local LBC communication | LBC locally via UDP |
| CT sensor path | Supported in load balancing scenario |
| Smart meter path | Smart Meter / P1 / HAN / ADL400 paths by project configuration |
| Wired load balancer | Wired load balancer configuration for Caro Plus |
| Wireless load balancer | Wireless load balancer configuration for Caro Plus |
| Nordic reader note | Reader-focused configuration mentioned for Nordic countries |
| EMS & Communication | EMS integration | EMS Modbus RTU (OTA) / TCP |
| Network connection | Wi-Fi + Ethernet + Bluetooth / Wi-Fi + 4G + Bluetooth |
| OCPP | OCPP 1.6 JSON |
| OCPP upgrade path | OCPP 2.0.1J upgradeable by firmware / project confirmation |
| App operation | EN Plus App operation / AP Mode by configuration |
| Platform path | EVchargo / EVcharCloud path shown in product introduction diagrams |
| Connector & User Access | Connector options | Type 2 Cable / T2 Socket / T2S Socket for France |
| Cable length | 5m cable version |
| Start mode | Plug to Charge / RFID card / App |
| Secure RFID reader | Optional; DESFire Duox / FeliCa / NFC upgradable by configuration |
| RFID reader | Mifare ISO/IEC 14443-A and related secure RFID configuration by project |
| Installation | Installation method | Wall-mount / pole-mount installation |
| Cabling method | Rear cabling / bottom cabling |
| Front cover opening | Tool-less manual front cover opening |
| AC input cable inlet | Optional rear cabling AC input cable inlet |
| Communication cable inlet | Optional rear cabling communication cable inlet |
| Maintenance focus | Designed for easier wiring and maintenance access compared with previous-generation structures |
| Safety & Compliance | Cybersecurity | EN 18031-1 / UTAC pentest / EN 303645 direction according to product introduction |
| Cybersecurity hardware | Encryption chip and cybersecurity design direction by configuration |
| RCD | 30mA Type A + 6mA DC |
| Relay-sticking protection | Project confirmation required | Supported for 11kW |
| EnWG §14a | Meets EnWG §14a according to product introduction |
| Dry contact | Project confirmation required | Dry Contact 4.2kW for 11kW configuration |
| PEN fault | UK M1a configuration should be confirmed by project |
| Impact protection | IK10 |
| Environmental / certification listing | RoHS / REACH / CE / CB / UKCA / CE-RED listed in product introduction; final certificate package should be checked before market launch |
| Protection & Environment | Ingress protection | Socket version IP54 / cable version IP65 by configuration |
| Operating temperature | -30°C to +50°C |
| Operating humidity | 5%–95% non-condensing |
| Operating altitude | ≤2000m |
| Warranty | 2 years |
| Packaging & Documents | Packaging direction | Cardboard packaging; eco-friendly packaging direction with high recyclability claim should be confirmed before publication |
| Main documents | Product datasheet; brochure; instruction sheet |
| Quick installation guide | Installation guide / QR code content to be inserted after final documentation is available |